Find the true price/cost of air conditioner, heat pump, furnace, heating /cooling system







HVAC




Location & Time Air Condtioning System Price Cost Notes
Boston, Massachusetts, October, 2010
Trane Furnace:
TUH1B060A9361A 5.0 ton(60,000BTU)
Trane Air conditioner:
4TTR3030A1000A 2.5 ton(30,000BTU)
Trane Thermostat:
TCONT600AF11MA
Trane Coil:
4TXCB031BC3HCA
7200
2410 media air filtration device with merv 13 performance 16x25x5 is $265,
Massachusetts, August, 2010
Carrier Air conditioner:
Performance series 24APA736A003 3.0 ton(36,000BTU)
Carrier Coil:
Infinity series FE4ANB003T00
Carrier Thermostat:
SYSTXCCUID01-B
Aprilaire Airquality:
2410 air cleaner
8701
Massachusetts, August, 2010
Heil Air conditioner:
4TEE3F66A1 3.0 ton(36,000BTU)
Heil Coil:
FVM4X48
6908
A free Aprilaire high efficiency air cleaner with a value of $ 575.00 to be installed at no
charge. 
Massachusetts, August, 2010
American Standard Air conditioner:
4A7A5036E1 3.0 ton(36,000BTU)
American Standard Coil:
4TEE3C04A1
7434
Massachusetts, August, 2010
Carrier Air conditioner:
24ABB336A003 3.0 ton(36,000BTU)
Carrier Coil:
FB4CNF03600
5703
-Honeywell Pro 6000 programmable thermostat
-Aprilaire 2410 air media cleaner
-All ductwork require to reconnect the supply and return ducts to the new air handler
-All electrical power and control wiring
-Refrigerant recovery
-Demo and removal of old equipment
-All miscellaneous material and labor to install
-Applicable sales tax and permit fees. 
Massachusetts, June, 2010
Bryant Air conditioner:
288 ANA 036 3.0 ton(36,000BTU)
Bryant Coil:
FE4ANFOOST
8075
Massachusetts, October, 2011
Carrier Heatpump:
25HNB648 4.0 ton(48,000BTU)
Carrier Furnace:
M-58MVC120-20 10.0 ton(120,000BTU)
Carrier Coil:
CNPV6124A
11250
About us: 3000 sq ft 2-story house in southern Maryland.
Included in this quote: Complete ToraVac Source Removal System (is this duct cleaning? If so, it is actually ~$500 extra) 
10 year parts, 2 year labor, 10 year compressor, 20 year heat exchanger warranty

$11,250 before rebates, claiming $500 fed tax credit, $1100 Carrier rebate, $400 SMECO (local electric co-op) rebate = $9250 
Boston, Massachusetts, August, 2011
American Standard Furnace:
AUH2b060A9V3VA 7.5 ton(90,000BTU)
American Standard Air conditioner:
2.5 ton(30,000BTU)
American Standard Furnace:
AUH2b060A9V3VA 7.5 ton(90,000BTU)
American Standard Air conditioner:
4A7A3030D1000A 2.5 ton(30,000BTU)
22000
Boston, Massachusetts, October, 2012
Carrier Furnace:
tdd2b060a9v3va 5.0 ton(60,000BTU)
Carrier Air conditioner:
4ttr5030e1000a 2.5 ton(30,000BTU)
Carrier Coil:
4txcb031bc3hca
8200
infinity control 
new lineset,new condensate pump, etc.
Boston, Massachusetts, June, 2013
Carrier Air conditioner:
24ANB630A 2.5 ton(30,000BTU)
Carrier Coil:
FE4ANF002
Carrier Thermostat:
SYSTXCCUINWI-FI INFINITY PROGRAMMABLE THERMOSTAT
8890
- PRE FORMED CONCRETE PAD 
- METAL GALVANIZED 26 GAUGE TRUNK AND A RETURN PLENUM, AND SUPPLY TRANSITION PIECE. 
- TO DISCONNECT AND THEN RECONNECT THE EXISTING DUCT WORK. 
- TO INSTALL PVC DRAIN WITH TRAP. 
- TO RECONNECT THE COPPER REFRIGERATION LINES FROM CONDENSER AND TO THE EVAPORATOR COIL. 
- TO INSULATE THE SUCTION LINES WITH ARMORFLEX. 
- TO BRAZE ALL COPPER FITTINGS. 
- TO DISCONNECT AND RECONNECT ALL ELECTRICAL. 
- TO MAKE SURE YOU HAVE A NEW SAFETY PAN AND SWITCH UNDER THE NEW UNIT. 
- TO INCLUDE ALL ELECTRICAL NEEDED FOR THE NEW SYSTEM.

10 YEAR WARRANTY ON ALL PARTS. 
2 YEAR WARRANTY ON ALL LABOR.
Massachusetts, April, 2014
Carrier Heatpump:
25VNA036A003 3.0 ton(36,000BTU)
Carrier Coil:
FE4ANF005
Carrier Auxiliary Heat:
KFCEH1601315 10 kw electric heater, 2 stages (5kw,15kw) 1.0 ton(12,000BTU)
19000
Work includes:

-Remove and dispose of oil furnace, oil tank and metal chimney. 
-Installation and connection to existing duct work. 
-Install new insulated steel duct work up to second floor with supplies into 3 bedrooms. (current duct work is not getting any flow) 
-Install new floor return grille on first floor. 
-Concrete pad for heat pump. 
-All power and control wiring from existing service panel.
Massachusetts, April, 2014
Lennox Heatpump:
Lennox XP17 Heat Pump 1.0 ton(12,000BTU)
Lennox Coil:
CBWMV -048/60C Hydro-coil Air Handler
20700 Minor duct work,
 the house is a ranch - 3,000 sq. ft., about 2,100 first level, 900 basement.

10 year factory warranty on all covered components 
Single stage operation 
Additional material: 
Refrigerant piping 
Digital Thermostat 
System suspended with threaded rod, uni-strut, and drain pan in attic 
Air Quality: 
Built in MERV 10 air filtration 
Duct Work 
Properly designed trunk with correct number of supply outlets to primary living level and outlets through closet areas to basement level 
Properly designed return with grill and filter 
Massachusetts, March, 2014
Trane Heatpump:
4TWX5036B1 Xli 15 High Efficiency 3.0 ton(36,000BTU)
Trane Coil:
TAM7A0C42H31 Trane Hyperion Air Handler with Variable Speed
Trane Auxiliary Heat:
BAYEV Trane Heater 1.0 ton(12,000BTU)
9500 Install new lineset,
HVAC


Heat Pump Prices Blog Furnace Prices Blog Compare Electric Rates & Plans 401k limit IRA contribution limit